{"id":22199,"date":"2023-03-16T14:05:24","date_gmt":"2023-03-16T18:05:24","guid":{"rendered":"https:\/\/polarislabs.com\/?p=22199"},"modified":"2025-08-18T11:26:21","modified_gmt":"2025-08-18T15:26:21","slug":"sampling-devices-find-the-right-one-for-your-program","status":"publish","type":"post","link":"https:\/\/polarislabs.com\/es\/sampling-devices-find-the-right-one-for-your-program\/","title":{"rendered":"Dispositivos de muestreo: Encuentre el adecuado para su programa"},"content":{"rendered":"<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-22203 size-full\" src=\"https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/03\/Sampling-devices.png\" alt=\"\" width=\"1100\" height=\"400\" srcset=\"https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/03\/Sampling-devices.png 1100w, https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/03\/Sampling-devices-300x109.png 300w, https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/03\/Sampling-devices-1030x375.png 1030w, https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/03\/Sampling-devices-768x279.png 768w, https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/03\/Sampling-devices-705x256.png 705w\" sizes=\"auto, (max-width: 1100px) 100vw, 1100px\" \/><\/p>\n<p>Los dispositivos de muestreo se utilizan para extraer muestras de lubricante, refrigerante o combustible de los componentes del sistema. Existe una amplia gama de dispositivos de muestreo para satisfacer necesidades espec\u00edficas, pero pueden agruparse en dos categor\u00edas b\u00e1sicas: 1) bombas de vac\u00edo y 2) dispositivos de muestreo instalados.<\/p>\n<p><strong>Bombas de vac\u00edo<\/strong><\/p>\n<div id=\"attachment_22201\" style=\"width: 310px\" class=\"wp-caption alignright\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-22201\" class=\"wp-image-22201 size-medium\" src=\"https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/03\/4.-Use-vacuum-pump-300x168.png\" alt=\"\" width=\"300\" height=\"168\" srcset=\"https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/03\/4.-Use-vacuum-pump-300x168.png 300w, https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/03\/4.-Use-vacuum-pump-1030x578.png 1030w, https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/03\/4.-Use-vacuum-pump-768x431.png 768w, https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/03\/4.-Use-vacuum-pump-1536x862.png 1536w, https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/03\/4.-Use-vacuum-pump-2048x1150.png 2048w, https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/03\/4.-Use-vacuum-pump-1500x842.png 1500w, https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/03\/4.-Use-vacuum-pump-705x396.png 705w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><p id=\"caption-attachment-22201\" class=\"wp-caption-text\"><em>bomba de vac\u00edo<\/em><\/p><\/div>\n<p>Las bombas de vac\u00edo extraen l\u00edquido del dep\u00f3sito de un componente. Se introduce un tubo desechable a trav\u00e9s de la bomba y en un frasco de muestras atornillado a la bomba. El otro extremo del tubo se utiliza para acceder al dep\u00f3sito del componente. El vac\u00edo de la bomba extrae el fluido del dep\u00f3sito y lo introduce en el tarro de muestras sin que entre en contacto con la bomba. Los residuos de aceite en el tubo contaminar\u00edan futuras muestras, por lo que debe desecharse. La bomba en s\u00ed nunca toc\u00f3 el fluido y puede reutilizarse sin necesidad de limpiarla.<\/p>\n<p><strong>Dispositivos de muestreo instalados<\/strong><\/p>\n<p>Com\u00fanmente denominados \"v\u00e1lvulas\", los peque\u00f1os dispositivos de muestreo se instalan en los componentes para crear un puerto permanente y de f\u00e1cil acceso para extraer muestras. El uso de v\u00e1lvulas para extraer fluidos suele <strong>m\u00e1s r\u00e1pido<\/strong> que utilizando \u00fanicamente bombas de vac\u00edo. Las v\u00e1lvulas tambi\u00e9n <strong>minimizar las posibilidades de contaminaci\u00f3n ambiental<\/strong> que entra en la muestra o en el sistema de fluidos. Estos dispositivos permanentes recogen la <strong>muestras lo m\u00e1s representativas posible<\/strong> en el menor tiempo posible. Los dos tipos m\u00e1s comunes difieren en funci\u00f3n de si el sistema est\u00e1 presurizado o no.<\/p>\n<p><strong>Pulsador (4-100 PSI)<\/strong> - Al pulsar un bot\u00f3n del dispositivo se abre el puerto. La presi\u00f3n del sistema empuja el fluido a trav\u00e9s del puerto y lo introduce en un frasco de muestras abierto que se mantiene debajo de la v\u00e1lvula.<\/p>\n<div id=\"attachment_22200\" style=\"width: 240px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-22200\" class=\"wp-image-22200\" src=\"https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/03\/Hydraulic-Sampling-push-button.jpg\" alt=\"\" width=\"230\" height=\"187\" srcset=\"https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/03\/Hydraulic-Sampling-push-button.jpg 1666w, https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/03\/Hydraulic-Sampling-push-button-300x245.jpg 300w, https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/03\/Hydraulic-Sampling-push-button-1030x841.jpg 1030w, https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/03\/Hydraulic-Sampling-push-button-768x627.jpg 768w, https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/03\/Hydraulic-Sampling-push-button-1536x1254.jpg 1536w, https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/03\/Hydraulic-Sampling-push-button-1500x1224.jpg 1500w, https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/03\/Hydraulic-Sampling-push-button-495x400.jpg 495w, https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/03\/Hydraulic-Sampling-push-button-845x684.jpg 845w, https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/03\/Hydraulic-Sampling-push-button-705x576.jpg 705w\" sizes=\"auto, (max-width: 230px) 100vw, 230px\" \/><p id=\"caption-attachment-22200\" class=\"wp-caption-text\"><em>v\u00e1lvula de pulsador<\/em><\/p><\/div>\n<p><strong>Pasador de empuje (4-1000 PSI)<\/strong> - La inserci\u00f3n de un \"pin\" o \"aguja\" en el dispositivo abre el puerto. La presi\u00f3n del sistema o una bomba de vac\u00edo mueven el fluido a trav\u00e9s del tubo conectado a la clavija. Cuando no se utiliza una bomba de vac\u00edo, se enrosca un tap\u00f3n en el frasco de muestras para asegurar el otro extremo del tubo. La clavija, el tubo y la tapa no pueden limpiarse f\u00e1cilmente y deben desecharse.<\/p>\n<div id=\"attachment_22202\" style=\"width: 240px\" class=\"wp-caption alignleft\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-22202\" class=\"wp-image-22202\" src=\"https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/03\/sampling-with-valve-3-Logoless-sml-300x225.jpg\" alt=\"\" width=\"230\" height=\"173\" srcset=\"https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/03\/sampling-with-valve-3-Logoless-sml-300x225.jpg 300w, https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/03\/sampling-with-valve-3-Logoless-sml-1030x773.jpg 1030w, https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/03\/sampling-with-valve-3-Logoless-sml-768x576.jpg 768w, https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/03\/sampling-with-valve-3-Logoless-sml-705x529.jpg 705w, https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/03\/sampling-with-valve-3-Logoless-sml.jpg 1388w\" sizes=\"auto, (max-width: 230px) 100vw, 230px\" \/><p id=\"caption-attachment-22202\" class=\"wp-caption-text\">v\u00e1lvula de clavija<\/p><\/div>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Los dispositivos de muestreo instalados ahorran tiempo<\/strong><strong> Y dinero<\/strong><\/p>\n<p>Una bomba de vac\u00edo puede extraer muestras de varios componentes, pero lo hace m\u00e1s lentamente que un dispositivo de muestreo instalado. <strong>Por lo general, la reducci\u00f3n del tiempo de muestreo permite amortizar el dispositivo y su instalaci\u00f3n al cabo de cinco muestras.<\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-22206\" src=\"https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/03\/sample-valve-ROI.png\" alt=\"\" width=\"363\" height=\"246\" srcset=\"https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/03\/sample-valve-ROI.png 934w, https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/03\/sample-valve-ROI-300x204.png 300w, https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/03\/sample-valve-ROI-768x521.png 768w, https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/03\/sample-valve-ROI-705x479.png 705w\" sizes=\"auto, (max-width: 363px) 100vw, 363px\" \/><\/p>\n<p>\u00bfA qu\u00e9 est\u00e1 esperando? Pida sus dispositivos de muestreo (es decir, Push Button o Push Pin) a trav\u00e9s de HORIZON Store, inst\u00e1lelos cuanto antes y empiece a ahorrar a\u00fan m\u00e1s dinero con su programa de an\u00e1lisis de fluidos.<\/p>\n<p>Maximice la fiabilidad de sus activos y recupere el control de sus programas de producci\u00f3n con un eficaz programa de an\u00e1lisis de fluidos de POLARIS Laboratories.<sup>\u00ae<\/sup> . . cuesta tan poco proteger tanto.<\/p>\n<p><em>Impacto probado. Tiempo de actividad probado. Ahorro probado.<\/em><\/p>\n<p><strong>D\u00e9jenos demostr\u00e1rselo.<\/strong><\/p>\n<p>Publicado el 16 de marzo de 2023<\/p>","protected":false},"excerpt":{"rendered":"<p>Sampling devices are used to pull samples of lubricant, coolant or fuel out of system components. There is a range of sampling devices to fulfill specific needs, but they can [&hellip;]<\/p>\n","protected":false},"author":8,"featured_media":22204,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"om_disable_all_campaigns":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"categories":[7,187,3],"tags":[],"class_list":["post-22199","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog","category-oil-testing","category-resources"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/polarislabs.com\/es\/wp-json\/wp\/v2\/posts\/22199","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/polarislabs.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/polarislabs.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/polarislabs.com\/es\/wp-json\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/polarislabs.com\/es\/wp-json\/wp\/v2\/comments?post=22199"}],"version-history":[{"count":0,"href":"https:\/\/polarislabs.com\/es\/wp-json\/wp\/v2\/posts\/22199\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/polarislabs.com\/es\/wp-json\/wp\/v2\/media\/22204"}],"wp:attachment":[{"href":"https:\/\/polarislabs.com\/es\/wp-json\/wp\/v2\/media?parent=22199"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/polarislabs.com\/es\/wp-json\/wp\/v2\/categories?post=22199"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/polarislabs.com\/es\/wp-json\/wp\/v2\/tags?post=22199"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}