{"id":23258,"date":"2023-11-14T11:29:19","date_gmt":"2023-11-14T16:29:19","guid":{"rendered":"https:\/\/polarislabs.com\/?p=23258"},"modified":"2024-01-08T12:26:29","modified_gmt":"2024-01-08T17:26:29","slug":"seeing-proven-savings-one-report-at-a-time","status":"publish","type":"post","link":"https:\/\/polarislabs.com\/es\/seeing-proven-savings-one-report-at-a-time\/","title":{"rendered":"Ahorros probados: Informe a informe"},"content":{"rendered":"<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-23267\" src=\"https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/11\/See-the-savings-featured-4.png\" alt=\"\" width=\"1100\" height=\"400\" srcset=\"https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/11\/See-the-savings-featured-4.png 1100w, https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/11\/See-the-savings-featured-4-300x109.png 300w, https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/11\/See-the-savings-featured-4-1030x375.png 1030w, https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/11\/See-the-savings-featured-4-768x279.png 768w, https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/11\/See-the-savings-featured-4-18x7.png 18w, https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/11\/See-the-savings-featured-4-705x256.png 705w\" sizes=\"auto, (max-width: 1100px) 100vw, 1100px\" \/><\/p>\n<p>El an\u00e1lisis de fluidos es una poderosa herramienta en la caja de herramientas de mantenimiento preventivo de muchos gestores de equipos y mantenimiento en industrias que van desde la construcci\u00f3n a los \u00e1ridos, pasando por la miner\u00eda y la marina. Los programas gestionados eficazmente proporcionan beneficios considerables que se traducen directamente en ahorros de costes de mantenimiento para las industrias que dependen del funcionamiento de sus equipos.<\/p>\n<p>Cuando se utilizan equipos, es inevitable que se produzca cierto desgaste a medida que la m\u00e1quina funciona durante horas. Una de las ventajas m\u00e1s valiosas del an\u00e1lisis de fluidos es la detecci\u00f3n de signos tempranos de desgaste en los equipos mediante el an\u00e1lisis de part\u00edculas de desgaste en el aceite.<\/p>\n<p><strong>Ahorro de $80.000 en costes de sustituci\u00f3n de motores<\/strong><\/p>\n<p>Uno de los clientes de POLARIS Laboratories\u00ae del sector naval pudo ahorrarse la sustituci\u00f3n completa de un motor realizando las acciones recomendadas en un informe de muestra de an\u00e1lisis de lubricante de alta gravedad. Despu\u00e9s de recoger una muestra de aceite durante una pausa en el programa de cambio de aceite, el informe de la muestra de la empresa arroj\u00f3 una severidad alta. La acci\u00f3n de mantenimiento recomendada, basada en los resultados de la prueba y la interpretaci\u00f3n, fue realizar un boroscopio en los cilindros, en el que el equipo observ\u00f3 estr\u00edas en las camisas de los cilindros.<\/p>\n<div id=\"attachment_23260\" style=\"width: 499px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-23260\" class=\"wp-image-23260\" src=\"https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/11\/Marine-Customer-Sample-Report.png\" alt=\"\" width=\"489\" height=\"355\" srcset=\"https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/11\/Marine-Customer-Sample-Report.png 671w, https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/11\/Marine-Customer-Sample-Report-300x218.png 300w, https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/11\/Marine-Customer-Sample-Report-18x12.png 18w\" sizes=\"auto, (max-width: 489px) 100vw, 489px\" \/><p id=\"caption-attachment-23260\" class=\"wp-caption-text\"><em>Informe con niveles elevados de hierro y recomendaci\u00f3n de revisar los cilindros<\/em><\/p><\/div>\n<p>Mientras se segu\u00eda investigando el problema, se observ\u00f3 que la parte inferior de la cabeza del pist\u00f3n del motor mostraba signos de deterioro. Tras descubrirlo, se tom\u00f3 la decisi\u00f3n estrat\u00e9gica de mantenimiento de sustituir los seis pistones, las camisas y las bielas.<\/p>\n<p>Al compartir la empresa esta historia con POLARIS Laboratories\u00ae, se observ\u00f3 que no hab\u00eda otras indicaciones o alarmas de monitorizaci\u00f3n de estado que mostraran que hab\u00eda un problema en el motor - la preocupaci\u00f3n s\u00f3lo se identific\u00f3 bas\u00e1ndose en los resultados de las pruebas y las recomendaciones del informe de muestra del an\u00e1lisis del lubricante. Sin el informe de la muestra que indicaba un desgaste anormal y la sugerencia de evaluar los cilindros, el problema no se habr\u00eda identificado y habr\u00eda provocado una p\u00e9rdida total del motor y $80.000.<\/p>\n<p><strong>Evitar p\u00e9rdidas de producci\u00f3n, tiempos de inactividad y p\u00e9rdidas de m\u00e1s de $260.000 en motores<\/strong><\/p>\n<p>Para un cliente de POLARIS Laboratories\u00ae del sector de los \u00e1ridos, el tiempo de inactividad del equipo puede ser perjudicial para la producci\u00f3n, la satisfacci\u00f3n del cliente, los costes de mano de obra y las operaciones. El informe del an\u00e1lisis del refrigerante de la empresa indicaba un punto de congelaci\u00f3n elevado que, si no se solucionaba, habr\u00eda provocado la congelaci\u00f3n del bloque motor, lo que habr\u00eda supuesto la sustituci\u00f3n completa del motor por un importe de $135.000 (sin incluir el tiempo de inactividad si el equipo estaba fuera de producci\u00f3n para su reparaci\u00f3n).<\/p>\n<p>En otro caso, la empresa pudo evitar la reconstrucci\u00f3n completa de un eje, que habr\u00eda costado $50.000, abordando un problema sencillo y sustituyendo el aceite despu\u00e9s de que un informe de an\u00e1lisis de lubricantes arrojara resultados que indicaban una fuga en el eje que hab\u00eda provocado la contaminaci\u00f3n por suciedad causante del desgaste.<\/p>\n<div id=\"attachment_23259\" style=\"width: 481px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-23259\" class=\"wp-image-23259\" src=\"https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/11\/Aggregate-Customer-Sample-Report.png\" alt=\"\" width=\"471\" height=\"351\" srcset=\"https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/11\/Aggregate-Customer-Sample-Report.png 3842w, https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/11\/Aggregate-Customer-Sample-Report-300x224.png 300w, https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/11\/Aggregate-Customer-Sample-Report-1030x768.png 1030w, https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/11\/Aggregate-Customer-Sample-Report-768x572.png 768w, https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/11\/Aggregate-Customer-Sample-Report-1536x1145.png 1536w, https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/11\/Aggregate-Customer-Sample-Report-2048x1526.png 2048w, https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/11\/Aggregate-Customer-Sample-Report-16x12.png 16w, https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/11\/Aggregate-Customer-Sample-Report-1500x1118.png 1500w, https:\/\/polarislabs.com\/wp-content\/uploads\/2023\/11\/Aggregate-Customer-Sample-Report-705x525.png 705w\" sizes=\"auto, (max-width: 471px) 100vw, 471px\" \/><p id=\"caption-attachment-23259\" class=\"wp-caption-text\"><em>Informe que muestra niveles elevados de sodio con la recomendaci\u00f3n de comprobar si hay fugas en el sistema de refrigeraci\u00f3n.<\/em><\/p><\/div>\n<p>Recientemente, la empresa salv\u00f3 un equipo gracias a un an\u00e1lisis de aceite y recibi\u00f3 un informe que indicaba altos niveles de plomo. El equipo pudo sustituir de forma proactiva los refrigeradores NRS antes de que el motor se averiara, una aver\u00eda cuya reparaci\u00f3n habr\u00eda costado a la empresa $75.000, adem\u00e1s de la p\u00e9rdida adicional de tiempo de inactividad.<\/p>\n<p>El an\u00e1lisis de fluidos es una herramienta de supervisi\u00f3n del estado proactiva, preventiva, predictiva y rentable que ha demostrado minimizar los costes de mantenimiento inesperados y no presupuestados al detectar signos de desgaste y contaminaci\u00f3n tempranos. Mediante la interpretaci\u00f3n de los resultados de las pruebas y las recomendaciones de mantenimiento proporcionadas por los analistas de datos, los responsables de mantenimiento y de los equipos pueden tomar medidas antes incluso de que se produzca un fallo.<\/p>\n<p><em>Impacto probado. Tiempo de actividad probado. Ahorro probado.<\/em><\/p>\n<p><strong>D\u00e9jenos demostr\u00e1rselo.<\/strong><\/p>\n<div class=\"entry-content\">\n<p>Publicado el 14 de noviembre de 2023<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Fluid analysis is a powerful tool in the preventive maintenance toolbox of many equipment and maintenance managers in industries ranging from construction to aggregates to mining to marine. Efficiently managed [&hellip;]<\/p>\n","protected":false},"author":8,"featured_media":23266,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"om_disable_all_campaigns":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"categories":[7,186,185,187,3],"tags":[],"class_list":["post-23258","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog","category-coolant-testing","category-fuel-testing","category-oil-testing","category-resources"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/polarislabs.com\/es\/wp-json\/wp\/v2\/posts\/23258","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/polarislabs.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/polarislabs.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/polarislabs.com\/es\/wp-json\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/polarislabs.com\/es\/wp-json\/wp\/v2\/comments?post=23258"}],"version-history":[{"count":0,"href":"https:\/\/polarislabs.com\/es\/wp-json\/wp\/v2\/posts\/23258\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/polarislabs.com\/es\/wp-json\/wp\/v2\/media\/23266"}],"wp:attachment":[{"href":"https:\/\/polarislabs.com\/es\/wp-json\/wp\/v2\/media?parent=23258"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/polarislabs.com\/es\/wp-json\/wp\/v2\/categories?post=23258"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/polarislabs.com\/es\/wp-json\/wp\/v2\/tags?post=23258"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}