{"id":23663,"date":"2024-03-21T11:23:55","date_gmt":"2024-03-21T15:23:55","guid":{"rendered":"https:\/\/polarislabs.com\/?p=23663"},"modified":"2025-08-11T11:28:44","modified_gmt":"2025-08-11T15:28:44","slug":"assessing-methods-to-analyze-particles-pq-vs-ferroq","status":"publish","type":"post","link":"https:\/\/polarislabs.com\/es\/assessing-methods-to-analyze-particles-pq-vs-ferroq\/","title":{"rendered":"Evaluaci\u00f3n de m\u00e9todos para analizar part\u00edculas: PQ frente a FerroQ"},"content":{"rendered":"<p><a href=\"https:\/\/polarislabs.com\/wp-content\/uploads\/2024\/03\/PQ-Ferro-Q-header.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-23675\" src=\"https:\/\/polarislabs.com\/wp-content\/uploads\/2024\/03\/PQ-Ferro-Q-header.png\" alt=\"\" width=\"1100\" height=\"400\" \/><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-25210 size-full\" src=\"https:\/\/polarislabs.com\/wp-content\/uploads\/2025\/08\/PQ-Ferro-Q-header.png\" alt=\"\" width=\"1100\" height=\"400\" srcset=\"https:\/\/polarislabs.com\/wp-content\/uploads\/2025\/08\/PQ-Ferro-Q-header.png 1100w, https:\/\/polarislabs.com\/wp-content\/uploads\/2025\/08\/PQ-Ferro-Q-header-300x109.png 300w, https:\/\/polarislabs.com\/wp-content\/uploads\/2025\/08\/PQ-Ferro-Q-header-1030x375.png 1030w, https:\/\/polarislabs.com\/wp-content\/uploads\/2025\/08\/PQ-Ferro-Q-header-768x279.png 768w, https:\/\/polarislabs.com\/wp-content\/uploads\/2025\/08\/PQ-Ferro-Q-header-18x7.png 18w, https:\/\/polarislabs.com\/wp-content\/uploads\/2025\/08\/PQ-Ferro-Q-header-705x256.png 705w\" sizes=\"auto, (max-width: 1100px) 100vw, 1100px\" \/><\/a><\/p>\n<p><strong>\u00bfQu\u00e9 son los residuos ferrosos?<\/strong><\/p>\n<p>Los fragmentos met\u00e1licos que permanecen en el aceite lubricante se denominan residuos ferrosos y siempre han supuesto un obst\u00e1culo para los laboratorios de control de estado o las instalaciones de los usuarios finales. Hist\u00f3ricamente, los m\u00e9todos espectrosc\u00f3picos no han sido capaces de analizar completamente la carga de residuos ferrosos de menos de 10 \u00b5m de di\u00e1metro.<\/p>\n<p>Cr\u00e9dito del Swansea Tribology Centre, el PQ ha sido globalmente un componente esencial de los programas de control del estado del aceite desde 1985 para combatir las limitaciones del an\u00e1lisis completo. El PQ es un magnet\u00f3metro sensible que mide la influencia en un campo magn\u00e9tico y proporciona un resultado cuantitativo del desgaste ferroso en una muestra. Este resultado puede obtenerse con una linealidad aceptable en una amplia gama de concentraciones de residuos ferrosos y tama\u00f1os de part\u00edculas.<\/p>\n<p><strong>Limitaciones y soluciones de PQ<\/strong><\/p>\n<p>PQ viene con ciertas limitaciones que pueden interrumpir el proceso de recibir mediciones precisas de las cantidades de residuos ferrosos. Estas limitaciones incluyen mediciones de botellas que s\u00f3lo analizan alrededor del cent\u00edmetro inferior o est\u00e1ndares que no est\u00e1n disponibles en el fabricante, por lo que no son trazables al NIST. Adem\u00e1s, existe el problema de que los resultados no tienen unidades debido a que el \u00edndice PQ se refiere a un n\u00famero adimensional.<\/p>\n<p>Afortunadamente, los instrumentos m\u00e1s nuevos como Poseidon FerroQ fue desarrollado para cumplir con estas limitaciones que utiliza exclusivamente un conjunto de bobinas; una para la medici\u00f3n y otra para la referencia. Cuando se inserta la muestra, cualquier material ferroso presente en la muestra de aceite \/ grasa cambia la inductancia de la bobina de medici\u00f3n en relaci\u00f3n con la bobina de referencia. Un circuito sensible de acondicionamiento de se\u00f1ales detecta esos peque\u00f1os cambios en la inductancia de la bobina de medici\u00f3n y el procesador integrado interpreta esta se\u00f1al para proporcionar una salida de masa\/volumen basada en est\u00e1ndares de calibraci\u00f3n.<\/p>\n<p>Los productos de una sola bobina, como PQ y algunos dispositivos PPM, suelen dar resultados diferentes a los productos de bobina fija, como FerroQ. El resultado es un dispositivo muy sensible a las part\u00edculas de la parte inferior de la muestra e insensible a las de la parte superior. La bobina de medici\u00f3n de FerroQ rodea la muestra, proporcionando una sensibilidad uniforme y una repetibilidad superior.<\/p>\n<p><strong>\u00bfC\u00f3mo se mide FerroQ? <\/strong><\/p>\n<p>El FerroQ informa de los resultados en mg\/kg y utiliza est\u00e1ndares que son trazables NIST hasta un est\u00e1ndar de hierro primario. De este modo se obtiene un resultado cuantificable que cumple mejor las normas de calidad.<\/p>\n<p>Para confirmar la trazabilidad y exactitud de los resultados del FerroQ, se prepararon 0,0151 g de polvo de hierro, &lt;10 \u00b5m, \u226599,9% base de metal traza de Sigma Aldrich en 10,0007 g totales de una resina reactiva UV. El resultado te\u00f3rico fue de 1510 mg\/kg.<\/p>\n<table style=\"height: 210px;\" width=\"234\">\n<tbody>\n<tr>\n<td width=\"54\"><strong>Tubo<\/strong><\/td>\n<td width=\"97\"><strong>R\u00e9plica 1<\/strong><\/td>\n<td width=\"97\"><strong>R\u00e9plica 2<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"54\"><strong>#1<\/strong><\/td>\n<td width=\"97\">1620 mg\/kg<\/td>\n<td width=\"97\">1630 mg\/kg<\/td>\n<\/tr>\n<tr>\n<td width=\"54\"><strong>#2<\/strong><\/td>\n<td width=\"97\">1610 mg\/kg<\/td>\n<td width=\"97\">1640 mg\/kg<\/td>\n<\/tr>\n<tr>\n<td width=\"54\"><strong>#3<\/strong><\/td>\n<td width=\"97\">1590 mg\/kg<\/td>\n<td width=\"97\">1590 mg\/kg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>En algunos laboratorios existe el deseo de cambiar el venerable PQ por el FerroQ. Para determinarlo, se realizaron 1291 comparaciones.<\/p>\n<div id=\"attachment_23672\" style=\"width: 594px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/polarislabs.com\/wp-content\/uploads\/2025\/08\/PQ-FerroQ-Chart.png\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-23672\" class=\"wp-image-23672\" src=\"https:\/\/polarislabs.com\/wp-content\/uploads\/2025\/08\/PQ-FerroQ-Chart.png\" alt=\"\" width=\"584\" height=\"380\" \/><\/a><p id=\"caption-attachment-23672\" class=\"wp-caption-text\">El uso de todos los datos s\u00ed mostr\u00f3 que por encima de 1000 PQ\u2122 Index los datos s\u00ed ten\u00edan un sesgo. Esto es probablemente el efecto de PQ\u2122 no analiza toda la muestra.<\/p><\/div>\n<p>&nbsp;<\/p>\n<p>La eliminaci\u00f3n de estos datos muestra una correlaci\u00f3n clara entre los dos m\u00e9todos:<\/p>\n<p><a href=\"https:\/\/polarislabs.com\/wp-content\/uploads\/2024\/03\/PQ-FerroQ-Chart-2.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-23673\" src=\"https:\/\/polarislabs.com\/wp-content\/uploads\/2024\/03\/PQ-FerroQ-Chart-2.png\" alt=\"\" width=\"585\" height=\"381\" \/><\/a><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-25212 size-full\" src=\"https:\/\/polarislabs.com\/wp-content\/uploads\/2025\/08\/PQ-FerroQ-Chart-2.png\" alt=\"\" width=\"584\" height=\"380\" srcset=\"https:\/\/polarislabs.com\/wp-content\/uploads\/2025\/08\/PQ-FerroQ-Chart-2.png 975w, https:\/\/polarislabs.com\/wp-content\/uploads\/2025\/08\/PQ-FerroQ-Chart-2-300x195.png 300w, https:\/\/polarislabs.com\/wp-content\/uploads\/2025\/08\/PQ-FerroQ-Chart-2-768x499.png 768w, https:\/\/polarislabs.com\/wp-content\/uploads\/2025\/08\/PQ-FerroQ-Chart-2-18x12.png 18w, https:\/\/polarislabs.com\/wp-content\/uploads\/2025\/08\/PQ-FerroQ-Chart-2-705x458.png 705w\" sizes=\"auto, (max-width: 584px) 100vw, 584px\" \/><\/p>\n<p>En resumen, la tecnolog\u00eda FerroQ muestra un rendimiento similar al de la tecnolog\u00eda PQ. Esto, unido a que el FerroQ tiene est\u00e1ndares trazables NIST, informa en mg\/kg y analiza toda la muestra (en lugar de s\u00f3lo el fondo), puede ser un m\u00e9todo superior al venerable PQ.<\/p>\n<p><a href=\"https:\/\/polarislabs.com\/wp-content\/uploads\/2024\/03\/Swanson-Author.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-23674\" src=\"https:\/\/polarislabs.com\/wp-content\/uploads\/2024\/03\/Swanson-Author.png\" alt=\"\" width=\"330\" height=\"112\" \/><\/a><\/p>\n<p><em>Impacto probado. Tiempo de actividad probado. Ahorro probado.<\/em><\/p>\n<p><strong>D\u00e9jenos demostr\u00e1rselo.<\/strong><\/p>\n<div class=\"entry-content\">\n<p>Publicado el 21 de marzo de 2024<\/p>\n<p>&nbsp;<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>What is Ferrous Debris? The metallic fragments that linger onto lubrication oil are referred to as Ferrous Debris and have always posed an obstacle for condition monitoring laboratories or end-user [&hellip;]<\/p>\n","protected":false},"author":8,"featured_media":25209,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"om_disable_all_campaigns":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"categories":[7,187,3],"tags":[],"class_list":["post-23663","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog","category-oil-testing","category-resources"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/polarislabs.com\/es\/wp-json\/wp\/v2\/posts\/23663","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/polarislabs.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/polarislabs.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/polarislabs.com\/es\/wp-json\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/polarislabs.com\/es\/wp-json\/wp\/v2\/comments?post=23663"}],"version-history":[{"count":0,"href":"https:\/\/polarislabs.com\/es\/wp-json\/wp\/v2\/posts\/23663\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/polarislabs.com\/es\/wp-json\/wp\/v2\/media\/25209"}],"wp:attachment":[{"href":"https:\/\/polarislabs.com\/es\/wp-json\/wp\/v2\/media?parent=23663"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/polarislabs.com\/es\/wp-json\/wp\/v2\/categories?post=23663"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/polarislabs.com\/es\/wp-json\/wp\/v2\/tags?post=23663"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}